Sto Stucco Render System
Product Technical Statement: 104728
Cavity based stucco wall cladding system over stainless steel lath.
|
Level of assurance needed to demonstrate NZ Building Code Compliance
Supporting documentation should include technical information by manufacturer and either a BRANZ or independent Appraisal or CodeMark
|
|
Sto
confirms that this minimum level of assurance has been met or exceeded by the following:
BRANZ Appraisal 488 (2006)
|
Technical Statement
Scope of use
The StoStucco Render System has been appraised by BRANZ as an external
wall cladding system for buildings within the following scope:
-
the
scope limitations of NZBC Acceptable Solution E2/AS1, Paragraph 1.1; and,
- constructed
with timber framing complying with the NZBC; and,
- with
a risk score of 0-20, calculated in accordance with NZBC Acceptable
Solution E2/AS1, Table 2; and,
- situated
in NZS 3604 Wind Zones up to, and including Extra High.
StoStucco has also been appraised for weathertightness and structural
wind loading when used as an exterior wall cladding for buildings within the
following scope:
-
the
scope limitations of NZBC Acceptable Solution E2/AS1, Paragraph 1.1 with
regards to building height and floor plan area; and,
- constructed
with timber framing subject to specific engineering design; and,
- situated
in specific design wind pressures up to a maximum design differential
ultimate limit state (ULS) of 2.5 kPa.
StoStucco must only be installed on vertical surfaces (except for tops
of parapets, sills and balustrades).
The system is appraised for use with aluminium
window and door joinery that is installed with vertical jambs and horizontal
heads and sills.
New Zealand Building Code (NZBC)
The product will, if employed in accordance with the supplier's installation and maintenance requirements, assist with meeting the following provisions of the building code:
- Clause B1 Structure: Performance B1.3.1, B1.3.2, B1.3.3, B1.3.3(a), B1.3.3(h), B1.3.3(j), B1.3.3(q), B1.3.4
- Clause B2 Durability: Performance B2.3.1(b), B2.3.1(c), B2.3.2
- Clause C3 Fire affecting areas beyond the fire source: Performance C3.7
- Clause E2 External moisture: Performance E2.3.2
- Clause F2 Hazardous building materials: Performance F2.3.1
Notes
The StoStucco Render System meets the requirements of Performance
B2.3.1(b) 15 years for the render and cavity system, and the requirements
of Performance B2.3.1(c) 5 years for the paint finish.
The StoStucco Render System will not present a
health hazard to people.
Supporting evidence
The product has and can make available the following additional evidence to support the above statements:
Product Criteria
Design requirements
StoStucco is expected to have a serviceable life of at least 30 years
provided the system is maintained in accordance with the Sto Specification,
Warranty and BRANZ Appraisal, and the lath, fixings and renders are
continuously protected by a weathertight coating and remain dry in
service.
Studs must be at maximum 600 mm centres for buildings situated in NZS
3604 Wind Zones up to and including Extra High, and specifically designed
buildings in wind pressures up to and including design differential 2.5 kPa ULS.
The StoStucco render and finishing system has a
peak heat release rate of less than 100 kW/m2 and a total heat released of less than
25 MJ/m2. The system is suitable for use on buildings with a SH Risk Group
classification, at any distance to the relevant boundary. Refer to NZBC
Acceptable Solutions C/AS2 – C/AS6, Paragraph 5.8.1 for the specific exterior
surface finish requirements for other building Risk Groups.
For a breakdown of the
system components, Click Here.
Installation requirements
Installation and finishing of components and accessories supplied by
Stoanz Limited and the Sto registered contractor must be completed by trained
applicators, approved by Stoanz Limited.
Installation of the accessories supplied by the
building contractor must be carried out in accordance with the StoStucco Technical Literature and the BRANZ Appraisal by, or under the supervision of a
Licensed Building Practitioner (LBP) with the relevant Licence Class.
Maintenance requirements
Regular maintenance is essential to ensure the performance requirements
of the NZBC are continually met and to ensure the maximum serviceability of the
system. Carry out an annual inspection and record this on the Sto
Construction Systems Maintenance schedule.
Regular cleaning (at least annually) of the
paint coating is required to remove grime, dirt and organic growth and to
maximise the life and appearance of the coating. Grime may be removed by
brushing with a soft brush, warm water and detergent. The paint system
must be recoated at approximately 8-10 yearly intervals in accordance with
Stoanz Limited instructions. Clear sealer systems require recoating at 5-7
yearly intervals.
Warrantees
With an increasing emphasis on the implementation of servicing exterior
building elements, Sto has launched the StoArmat 20 Year Warranty and
StoService Assurance documentation. This system, administered by Sto and
carried out by Sto Contractors, ensures all specified StoArmat Rendered Systems
are registered, serviced and certified every two and a half years to provide
assurance that all building elements pertaining to the rendered facade are
performing.
Refer to the StoArmat Warranty Document by clicking here.
Environmental
Protecting the natural basis for life and improving
quality of life are important aims in social policy. Sto actively
pursues these aims, always acting in accordance with the company's
guiding principle: "Building with conscience."
In order to define and implement its ecological targets, Sto has
developed a system of environmental management conforming to
international standards. This relates to the entire process chain – from
the procurement of the raw product, to production, packaging and
logistics.
Quality Assurance
|
ISO 9001 (Quality Management) |
|
Date last validated:
07 July 2020 |
|
Date last updated:
07 July 2020 |
Disclaimer
The Product Technical Statement (PTS) template is copyright to Construction Information Limited. However the content of this PTS is the responsibility of the product manufacturer/supplier.
Refer to the miproducts Terms and Conditions
|
|